ELECTRIC HEATERS FOR AIR HANDLERS

Disclaimer:
Installation of any Heating or Cooling equipment must be done by persons trained in this Trade. Serious personal injury or death can occur by improper installations. Further, equipment warranty from the manufacturer will most likely be rejected from faulty installations. Furnaces installed at varying altitudes will require altering equipment parts. L.P. (Propane) installations require changing burner orifices and gas valve regulator springs with the proper factory supplied kit. Fuel pressure will need to be set using special equipment by an H.V.A.C. professional. (2) stage furnaces will require a 2 stage heating thermostat and related wiring for the furnace to function as it should. Pressure switches for your altitude will need to be ordered and the pressure switches in the furnace you receive ( which are installed for the Denver area ) will need to be replaced with these! Sheridan Mechanical Services will not be liable for any installations by others nor will we accept any responsibility for damages to people, equipment, buildings or parts.
Open any shipping cartons and examine contents for damage before accepting delivery so that you may make a claim to the Carrier on the spot as we will not be responsible for damages from shipping.

Heaters For All TWE-C/D; TWE-P; TWE-E; TWG; TVF; 4TEE; 4TEP

Heater Model Number KW @ 240 Volts Rated Voltage Heater Amps @ 240 Volts Contains Circuit Breakers
BAYHTR1405000 4.80 208/240/1/60 20 NO
BAYHTR1405BRK 4.80 208/240/1/60 20 YES
BAYHTR1405PDC 4.80 208/240/1/60 20 NO
BAYHTR1408000 7.68 208/240/1/60 32 NO
BAYHTR1408BRK 7.68 208/240/1/60 32 YES
BAYHTR1408PDC 7.68 208/240/1/60 32 NO
BAYHTR1410000 9.60 208/240/1/60 40 NO
BAYHTR1410BRK 9.60 208/240/1/60 40 YES
BAYHTR1410PDC 9.60 208/240/1/60 40 NO
BAYHTR1415BRK 15.36 208/240/1/60 40/24 * YES
BAYHTR1419BRK 19.20 208/240/1/60 40/24 * YES
BAYHTR1425BRK 24.96 208/240/1/60 44/40/20 * YES

000 = Pigtails only, BRK = Contains Circuit Breakers, PDC = Pull Disconnect
* Circuit 1/Circuit 2
Caution: Any power supply and/or combination power supply, circuit or circuits must be wired and protected in accordance with local electrical codes.