Google
 
Web www.sheridanhvac.com

Click here for a free, no obligation price quote from a local HVAC contractor

IF YOU NEED PARTS, PLEASE CLICK THE BANNER BELOW

 

 

 Clearance Sale on Compressors, Power Washers & Generators

 

Home
Articles:
Lung Cancer and YOUR Furnace or Boiler
CHECK OUT THIS NEW HOMEOWNERS BLOG.
FREE ADS FOR BUSINESSES!
   Homeowners Blog
 CATEGORIES
Table of Contents
Site Map
Contact
Search
Trane Rebates.
New 16 SEER
New 19.5 SEER
Trane Snowball
About Us
Testimonials
FAQ
New Trane Models
Humidifiers
T-Stats
Zoning
Elec.Air Cleaner
Carbon Monoxide
Furnace Repairs
Trane Furnaces
Trane AC Sale
Estimate
Add AC
Boilers
Install Photos
Commercial
Codes/Permits
Tight Homes
Low Air Flow
Heat Exchanger
Tips
Glossary
Troubleshooting
Internet Terms of Use
About Shipping
Equip Specs
Links
 

 


 



























 

 

 

 

 


Translate this Web Site to French, and other languages.
Tecleo aquí para una traducción española.
Cuando usted hace clic aquí usted irá a un sitio del traductor. Una vez que allí, pulse adentro a www.sheridanhvac.com en el traductor del Web page NO el rectángulo de texto.


   AIR HANDLER SPECIFICATIONS

 

Disclaimer:
Installation of any Heating or Cooling equipment must be done by persons trained in this Trade. Serious personal injury or death can occur by improper installations. Further, equipment warranty from the manufacturer will most likely be rejected from faulty installations. Furnaces installed at varying altitudes will require altering equipment parts. L.P. (Propane) installations require changing burner orifices and gas valve regulator springs with the proper factory supplied kit. Fuel pressure will need to be set using special equipment by an H.V.A.C. professional. (2) stage furnaces will require a 2 stage heating thermostat and related wiring for the furnace to function as it should. Pressure switches for your altitude will need to be ordered and the pressure switches in the furnace you receive ( which are installed for the Denver area ) will need to be replaced with these! Sheridan Mechanical Services will not be liable for any installations by others nor will we accept any responsibility for damages to people, equipment, buildings or parts.
Open any shipping cartons and examine contents for damage before accepting delivery so that you may make a claim to the Carrier on the spot as we will not be responsible for damages from shipping.

 

R-22 CONVERTIBLE, DUAL CIRCUIT, VARIABLE SPEED AIR HANDLER (below) FOR USE WITH (2) INDIVIDUAL CONDENSERS. ORDER ELECTRIC HEATERS SEPARATELY. FOR DOWNFLOW USE ORDER A DOWNFLOW SUB BASE FOR USE WITH COMBUSTIBLE FLOORING! CALL US WITH SIZE NEEDED.

Air Handler Shipping Costs

Tons Model Number Cooling Capacity (Btuh) FCCV Fan Speed Dimensions (in.)

H x W x D

Shipping Weight (lbs.) Supply Opening * Return Opening * Line Size Gas Line Size Liquid
3-6 TWE062E13FB 64,000 TXV (2) Variable 62 3/4 x 26 x 21 218 23 3/4 x 12 x 22 1/4 x 11 24 x 18

 

   


R-22 CONVERTIBLE, VARIABLE SPEED AIR HANDLER (12, 13, 14 and 18 S.E.E.R. HEAT PUMPS AND COOLING ONLY). ORDER ELECTRIC HEATERS SEPARATELY.
Order these air handlers below if you are trying to get an energy rebate from your power company. You will only get TRUE S.E.E.R. ratings IF you use these air handlers!
 FOR DOWNFLOW USE ORDER A DOWNFLOW SUB BASE FOR USE WITH COMBUSTIBLE FLOORING! CALL US WITH SIZE NEEDED.

Air Handler Shipping Costs

Tons Model Number Cooling Capacity (Btuh) FCCV Fan Speed Dimensions (in.)

H x W x D

Shipping Weight (lbs.) Supply Opening * Return Opening *
1 1/2-3 TWE031E13FB 31,000 TXV Variable 43 x 21 1/2 x 21 134 19 1/4x12 or 18 1/4x11 19 1/2x18
2-3 1/2 TWE037E13FB 37,000 TXV Variable 45 x 23 1/2 x 21 142 21 1/4x12 or 20 1/4x11 21 1/2x18
2-3 1/2 TWE040E13FB 40,000 TXV Variable 52 X 26 X 21 174 23 3/4X12 or 22 3/4x11 24 x 18
3-5 TWE049E13FB 49,000 TXV Variable 58 x 26 x 21 188 23 3/4x12 or 22 3/4x11 24 x 18
3 1/2-5 TWE065E13FB 65,000 TXV Variable 63 x 26 x 21 218 23 3/4x12 or 22 3/4x11 24 x 18


R -22 CONVERTIBLE STANDARD AIR HANDLER (10 S.E.E.R. HEAT PUMPS). ORDER ELECTRIC HEATERS SEPARATELY.
Order these air handlers if you are interested in the lowest price. These units will NOT qualify for energy rebates or supply true listed S.E.E.R. ratings.
 FOR DOWNFLOW USE ORDER A DOWNFLOW SUB BASE FOR USE WITH COMBUSTIBLE FLOORING! CALL US WITH SIZE NEEDED.

Air Handler Shipping Costs

Tons Model Number Cooling Capacity (Btuh) FCCV Fan Speed Dimensions (in.)

H x W x D

Shipping Weight (lbs.) Supply Opening * Return Opening *
1 1/2 TWG018A140B 18,000 .049 3 43X16X21 108 14X12 1/4 or 13x11 1/4 14x18 1/4
2 TWG025A140B 24,000 .055 3 45.7X18X21 124 16X12 1/4 or 15x11 1/4 16x18 1/4
2 1/2 TWG030A140B 30,000 .069 3 45.7X18X21 125 16X12 1/4 or 15x11 1/4 16x18 1/4
3 TWG036A140B 36,000 .071 3 52X18X21 135 16X12 1/4 or 15x11 1/4 16x18 1/4
3 TWG037A140B 37,000 .071 3 43X21 1/2X21 145 19 1/2X12 1/4 or 18 1/2x11 1/4 19 1/2x18 1/4
3 1/2 TWG042A140B 42,000 .080 3 43X23 1/2X21 160 21 1/2X12 1/4 or 20 1/2x11 1/4 21 1/2x18 1/4
4 TWG048A140B 48,000 .083 3 48.3X23 1/2X21 185 21 1/2X12 1/4 or 20 1/2x11 1/4 21 1/2x18 1/4
5 TWG060A150B 58,000 TXV 3 57.3X23 1/2X21 205 21 1/2X12 1/4 or 20 1/2x11 1/4 21 1/2x18 1/4


R410A REFRIGERANT- CONVERTIBLE, VARIABLE SPEED AIR HANDLER (below)(12, 13, 14 and 18 S.E.E.R. HEAT PUMPS/COOLING ONLY). ORDER ELECTRIC HEATERS SEPARATELY.
Order these air handlers if you are trying to get an energy rebate from your power company. You will only get TRUE S.E.E.R. ratings IF you use these air handlers!
 FOR DOWNFLOW USE ORDER A DOWNFLOW SUB BASE FOR USE WITH COMBUSTIBLE FLOORING! CALL US WITH SIZE NEEDED.

Air Handler Shipping Costs

Model Number Cooling Capacity (Btuh) FCCV Fan Speed Dimensions (in.)

H x W x D

Shipping Weight (lbs.) Supply Opening * Return Opening *
4TEE3F31A1000A 31,000 TXV Variable 43 x 21 1/2 x 21 134 19 1/4x12 or 18 1/4x11 19 1/2x18
4TEE3F37A1000A 37,000 TXV Variable 45 x 23 1/2 x 21 142 21 1/4x12 or 20 1/4x11 21 1/2x18
4TEE3F40A1000A 40,000 TXV Variable 52 X 26 X 21 174 23 3/4X12 or 22 3/4x11 24 x 18
4TEE3F49A1000A 49,000 TXV Variable 58 x 26 x 21 188 23 3/4x12 or 22 3/4x11 24 x 18
4TEE3F65A1000A 65,000 TXV Variable 63 x 26 x 21 218 23 3/4x12 or 22 3/4x11 24 x 18

NOTE:

R410A REFRIGERANT- CONVERTIBLE, (3) SPEED AIR HANDLER (12, 13,14 and 18 S.E.E.R. HEAT PUMPS / COOLING ONLY).(below) ORDER ELECTRIC HEATERS SEPARATELY.
These are high efficient air handlers with thermal expansion valves, but may not qualify for energy rebates with all power companies. Check with your power company BEFORE ordering any air handler! You may not get true published S.E.E.R. ratings with these units.
 FOR DOWNFLOW USE ORDER A DOWNFLOW SUB BASE FOR USE WITH COMBUSTIBLE FLOORING! CALL US WITH SIZE NEEDED.

Air Handler Shipping Costs

Model Number Cooling Capacity (Btuh) FCCV Fan Speed Dimensions (in.)

H x W x D

Shipping Weight (lbs.) Supply Opening * Return Opening *
4TEP3F18A1000A 18,000 TXV 3 43 x 21 1/2 x 21 114 19 1/4x12 or 18 1/4x11 19 1/2x18
4TEP3F24A1000A 24,000 TXV 3 43 x 21 1/2 x 21 121 21 1/4x12 or 20 1/4x11 21 1/2x18
4TEP3F30A1000A 30,000 TXV 3 43 X 21 1/2 X 21 121 23 3/4X12 or 22 3/4x11 24 x 18
4TEP3F36A1000A 36,000 TXV 3 45 x 21 1/2 x 21 135 23 3/4x12 or 22 3/4x11 24 x 18
4TEP3F42A1000A 42,000 TXV 3 52 x 23 1/2 x 21 165 23 3/4x12 or 22 3/4x11 24 x 18
4TEP3F48A1000A 48,000 TXV 3 57X26X21 188 23 3/4x12 or 22 3/4x11 24x18
4TEP3F63A1000A 60,000 TXV 3 63X26X21 211 23 3/4x12 or 22 3/4x11 24x18

Back to Equip. Specs.

Air Handler Shipping Costs 

 

 


 

All photos and text are original material published by Sheridan Mechanical Services 
and can not be distributed, or republished without written permission from 
Sheridan Mechanical Services.

UPDATED 05/08/2007 12:19 PM

© Copyright2001, 2002, 2003, 2004, 2005, 2006.  Sheridan Mechanical Services. All rights reserved.