ELECTRONIC AIR CLEANER SPECIFICATIONS

Disclaimer:
Installation of any Heating or Cooling equipment must be done by persons trained in this Trade. Serious personal injury or death can occur by improper installations. Further, equipment warranty from the manufacturer will most likely be rejected from faulty installations. Furnaces installed at varying altitudes will require altering equipment parts. L.P. (Propane) installations require changing burner orifices and gas valve regulator springs with the proper factory supplied kit. Fuel pressure will need to be set using special equipment by an H.V.A.C. professional. (2) stage furnaces will require a 2 stage heating thermostat and related wiring for the furnace to function as it should. Pressure switches for your altitude will need to be ordered and the pressure switches in the furnace you receive ( which are installed for the Denver area ) will need to be replaced with these! Sheridan Mechanical Services will not be liable for any installations by others nor will we accept any responsibility for damages to people, equipment, buildings or parts.
Open any shipping cartons and examine contents for damage before accepting delivery so that you may make a claim to the Carrier on the spot as we will not be responsible for damages from shipping.

 

HONEYWELL WHOLE HOUSE ELECTRONIC AIR CLEANERS: Mounts between return duct and furnace.

THE CHART BELOW SHOWS SPECS AND INTERNET PRICES IF WE SHIP A UNIT TO YOU FOR INSTALLATION BY A QUALIFIED INDIVIDUAL.

Model Number CFM.* Tons of 

A/C

Return cut out opening (in.) Internal Pressure switch** Power Supply Shipping
Weight
Power
Cord
F50F1040 1,000 2 1/2 12 1/2 X 20 yes 115/1/60 25 yes
F300E1001 1,200 3 16 X 20 yes 115/1/60 30 yes
F300E1019 1,400 3 1/2 16 x 25 yes 115/1/60 33 yes
F300E1027 1,400 3 1/2 20 x 20 yes 115/1/60 33 yes
F300E1035 2,000 5 20 x 25 yes 115/1/60 38 yes

* CFM = Cubic Feet of Air Per Minute. If you have central air conditioning this figure represents how much air can flow through the air cleaner. Each ton of air conditioning needs 400 C.F.M.

** Internal Pressure switch = Honeywell has a built in switch to NOT let the air cleaner work unless the furnace blower is running. This feature keeps from making Ozone which has an odor and can make a person irritable. You can also run the furnace blower continuously by selecting the "ON" position on your thermostat if you have central air conditioning, therefore cleaning your air all the time.