ELECTRONIC AIR CLEANER SPECIFICATIONS
Disclaimer:
Installation of any Heating or Cooling equipment must be done by persons trained
in this Trade. Serious personal injury or death can occur by improper
installations. Further, equipment warranty from the manufacturer will most
likely be rejected from faulty installations. Furnaces installed at varying
altitudes will require altering equipment parts. L.P. (Propane) installations
require changing burner orifices and gas valve regulator springs with the proper
factory supplied kit. Fuel pressure will need to be set using special equipment
by an H.V.A.C. professional. (2) stage furnaces will require a 2 stage heating
thermostat and related wiring for the furnace to function as it should. Pressure
switches for your altitude will need to be ordered and the pressure switches in
the furnace you receive ( which are installed for the Denver area ) will need to
be replaced with these! Sheridan Mechanical Services will not be liable for any
installations by others nor will we accept any responsibility for damages to
people, equipment, buildings or parts.
Open any shipping cartons and examine contents for damage before accepting
delivery so that you may make a claim to the Carrier on the spot as we will not
be responsible for damages from shipping.
HONEYWELL WHOLE HOUSE ELECTRONIC AIR CLEANERS: Mounts
between return duct and furnace.
THE CHART BELOW SHOWS SPECS AND INTERNET PRICES
IF WE SHIP A UNIT TO YOU FOR INSTALLATION BY A QUALIFIED INDIVIDUAL.
| Model Number |
CFM.* |
Tons of
A/C
|
Return cut out opening (in.) |
Internal Pressure switch** |
Power Supply |
Shipping
Weight |
Power
Cord |
| F50F1040 |
1,000 |
2 1/2 |
12 1/2 X 20 |
yes |
115/1/60 |
25 |
yes |
| F300E1001 |
1,200 |
3 |
16 X 20 |
yes |
115/1/60 |
30 |
yes |
| F300E1019 |
1,400 |
3 1/2 |
16 x 25 |
yes |
115/1/60 |
33 |
yes |
| F300E1027 |
1,400 |
3 1/2 |
20 x 20 |
yes |
115/1/60 |
33 |
yes |
| F300E1035 |
2,000 |
5 |
20 x 25 |
yes |
115/1/60 |
38 |
yes |
* CFM = Cubic Feet of Air Per Minute. If you have central air
conditioning this figure represents how much air can flow through
the air cleaner. Each ton of air conditioning needs 400 C.F.M.
** Internal Pressure switch = Honeywell has a built in switch to
NOT let the air cleaner work unless the furnace blower is running.
This feature keeps from making Ozone which has an odor and can make
a person irritable. You can also run the furnace blower continuously
by selecting the "ON" position on your thermostat if you
have central air conditioning, therefore cleaning your air all the
time.
Back to Equipment Specifications Equipment Specifications