Translate
this Web Site to French, and other languages.
Tecleo aquí para una traducción española.
Cuando usted hace clic aquí usted irá a un sitio del traductor. Una
vez que allí, pulse adentro a www.sheridanhvac.com en el traductor del
Web page NO el rectángulo de texto.
AIR CONDITIONING SPECIFICATIONS
Disclaimer:
Installation of any Heating or Cooling equipment must be done by persons trained
in this Trade. Serious personal injury or death can occur by improper
installations. Further, equipment warranty from the manufacturer will most
likely be rejected from faulty installations. Furnaces installed at varying
altitudes will require altering equipment parts. L.P. (Propane) installations
require changing burner orifices and gas valve regulator springs with the proper
factory supplied kit. Fuel pressure will need to be set using special equipment
by an H.V.A.C. professional. (2) stage furnaces will require a 2 stage heating
thermostat and related wiring for the furnace to function as it should. Pressure
switches for your altitude will need to be ordered and the pressure switches in
the furnace you receive ( which are installed for the Denver area ) will need to
be replaced with these! Refrigerant can not be bought, handled or installed by
any one who does not hold a Federal E.P.A. card for the particular
refrigerant. Refrigerant may need to be added for the system to operate
correctly and to not void the manufacturer's warranty! Sheridan Mechanical Services will not be liable for any
installations by others nor will we accept any responsibility for damages to
people, equipment, buildings or parts.
Open any shipping cartons and examine contents for damage before accepting
delivery so that you may make a claim to the Carrier on the spot as we will not
be responsible for damages from shipping.
XB1000 SPLIT SYSTEM AIR CONDITIONING - SINGLE
PHASE
(5) year warranty on all functional parts. 10 S.E.E.R. R-22
Air Conditioning Shipping Costs
| Model Number |
Power Supply |
Nom. Cap.
Cooling
(BTUH |
Required
FCCV
Size |
Uncrated
Height
|
Uncrated
Width |
Uncrated
Depth |
Shipping
Weight
(lbs.) |
Sound
Rating |
MCA* |
Max Fuse*
|
Line Size
Gas |
Line Size
Liquid |
| TTB012C100A |
200/230/1/60 |
12,000 |
.049 |
24 |
18 |
18 |
118 |
82 |
11 |
15 |
5/8 |
1/4 |
| TTB018C100A |
200/230/1/60 |
18,000 |
.049 |
24 |
18 |
18 |
118 |
82 |
11 |
15 |
5/8 |
1/4 |
| TTB024C100A |
200/230/1/60 |
24,000 |
.057 |
24 |
18 |
18 |
130 |
80 |
15 |
25 |
3/4 |
5/16 |
| TTB030C100A |
200/230/1/60 |
30,000 |
.065 |
26 |
25 |
25 |
176 |
78 |
18 |
30 |
3/4 |
5/16 |
| TTB036C100A |
200/230/1/60 |
36,000 |
.071 |
33 |
25 |
25 |
184 |
78 |
22 |
35 |
7/8 |
3/8 |
| TTB042D100A |
200/230/1/60 |
42,000 |
.077 |
33 |
25 |
25 |
176 |
78 |
28 |
45 |
7/8 |
3/8 |
| TTB048D100A |
200/230/1/60 |
48,000 |
.083 |
33 |
25 |
25 |
216 |
80 |
30 |
50 |
11/8 |
3/8 |
| TTB060D100A |
200/230/1/60 |
60,000 |
.092 |
41 |
33 |
29 |
265 |
79 |
38 |
60 |
11/8 |
3/8 |
XE1000 SPLIT SYSTEM AIR CONDITIONING - SINGLE PHASE
(5) year warranty on all functional parts. 10 S.E.E.R.
R-22
Air Conditioning Shipping Costs
| Model Number |
Power Supply |
Nom. Cap.
Cooling
(BTUH |
Required
FCCV
Size |
Uncrated
Height
|
Uncrated
Width |
Uncrated
Depth |
Shipping
Weight
(lbs.) |
Sound
Rating |
MCA* |
Max Fuse*
|
Line Size
Gas |
Line Size
Liquid |
| TTR018D100A |
200/230/1/60 |
18,000 |
.053 |
24 |
24 |
20 |
144 |
82 |
11 |
15 |
5/8 |
1/4 |
| TTR025C100A |
200/230/1/60 |
24,000 |
.055 |
24 |
24 |
20 |
144 |
82 |
15 |
25 |
3/4 |
5/16 |
| TTR030C100A |
200/230/1/60 |
30,000 |
.067 |
28 |
28 |
25 |
162 |
78 |
20 |
30 |
3/4 |
5/16 |
| TTR036D100A |
200/230/1/60 |
36,000 |
.071 |
28 |
28 |
25 |
163 |
78 |
26 |
45 |
7/8 |
3/8 |
| TTR042D100A |
200/230/1/60 |
42,000 |
.080 |
28 |
28 |
25 |
208 |
78 |
28 |
45 |
7/8 |
3/8 |
| TTR048D100A |
200/230/1/60 |
48,000 |
.083 |
33 |
33 |
29 |
213 |
78 |
31 |
50 |
11/8 |
3/8 |
| TTR060D100A |
200/230/1/60 |
60,000 |
.092 |
33 |
33 |
29 |
259 |
79 |
38 |
60 |
11/8 |
3/8 |
XR12 SPLIT SYSTEM AIR CONDITIONING - SINGLE PHASE - R-22
(10) year warranty on compressor and coil, (5)
years all functional parts. 12 S.E.E.R. R-22
Air Conditioning Shipping Costs
| Model Number |
Power Supply |
Nom. Cap.
Cooling
(BTUH |
Required
FCCV
Size |
Uncrated
Height
|
Uncrated
Width |
Uncrated
Depth |
Shipping
Weight
(lbs.) |
Sound
Rating |
MCA* |
Max Fuse*
|
Line Size
Gas |
Line Size
Liquid |
| 2TTR2018A1000A |
200/230/1/60 |
18,000 |
.051 |
26 |
29 |
26 |
171 |
NA |
10 |
15 |
5/8 |
1/4 |
| 2TTR2024A1000A |
200/230/1/60 |
24,000 |
.057 |
29 |
29 |
26 |
187 |
NA |
11 |
15 |
3/4 |
5/16 |
| 2TTR2030A1000A |
200/230/1/60 |
30,000 |
.065 |
29 |
29 |
26 |
180 |
NA |
15 |
25 |
3/4 |
5/16 |
| 2TTR2036A1000A |
200/230/1/60 |
36,000 |
.071 |
33 |
29 |
26 |
195 |
NA |
19 |
30 |
7/8 |
3/8 |
| 2TTR2042A1000A |
200/230/1/60 |
42,000 |
.077 |
33 |
30 |
30 |
228 |
NA |
24 |
40 |
7/8 |
3/8 |
| 2TTR2048A1000A |
200/230/1/60 |
48,000 |
.086 |
37 |
30 |
30 |
247 |
NA |
26 |
45 |
11/8 |
3/8 |
| 2TTR2060A1000A |
200/230/1/60 |
60,000 |
.095 |
37 |
30 |
30 |
270 |
NA |
38 |
60 |
11/8 |
3/8 |
XR12 SPLIT SYSTEM AIR CONDITIONING - SINGLE PHASE - 410-A
(10) year warranty on compressor and
coil, (5) years all functional parts. 12 S.E.E.R.
410A
Air Conditioning Shipping Costs
| Model Number |
Power Supply |
Nom. Cap.
Cooling
(BTUH |
Required
FCCV
Size |
Uncrated
Height
|
Uncrated
Width |
Uncrated
Depth |
Shipping
Weight
(lbs.) |
Sound
Rating |
MCA* |
Max Fuse*
|
Line Size
Gas |
Line Size
Liquid |
| 4TTR2018A1000A |
200/230/1/60 |
18,000 |
.049 |
33 |
33 |
30 |
215 |
77 |
10 |
15 |
1/2 |
1/4 |
| 4TTR2024A1000A |
200/230/1/60 |
24,000 |
.053 |
33 |
33 |
30 |
219 |
78 |
13 |
20 |
5/8 |
5/16 |
| 4TTR2030A1000A |
200/230/1/60 |
30,000 |
.059 |
33 |
33 |
30 |
218 |
74 |
20 |
30 |
3/4 |
5/16 |
| 4TTR2036A1000A |
200/230/1/60 |
36,000 |
.065 |
33 |
33 |
30 |
231 |
77 |
21 |
35 |
3/4 |
3/8 |
| 4TTR2042A1000A |
200/230/1/60 |
42,000 |
.071 |
37 |
33 |
30 |
243 |
78 |
25 |
40 |
3/4 |
3/8 |
| 4TTR2048A1000A |
200/230/1/60 |
48,000 |
.077 |
41 |
33 |
30 |
260 |
79 |
31 |
50 |
7/8 |
3/8 |
| 4TTR2060A1000A |
200/230/1/60 |
60,000 |
.083 |
33 |
37 |
34 |
283 |
81 |
36 |
60 |
7/8 |
3/8 |
XL13i SPLIT SYSTEM AIR CONDITIONING - SINGLE PHASE - 410-A
(10) year warranty on all
functional parts. 13 S.E.E.R. 410A
Air Conditioning Shipping Costs
| Model Number |
Power Supply |
Nom. Cap.
Cooling
(BTUH |
Required
FCCV
Size |
Uncrated
Height
|
Uncrated
Width |
Uncrated
Depth |
Shipping
Weight
(lbs.) |
Sound
Rating |
MCA* |
Max Fuse*
|
Line Size
Gas |
Line Size
Liquid |
| 4TTX3018A1000A |
200/230/1/60 |
18,000 |
.049 |
40 |
33 |
30 |
230 |
74/76 |
10 |
15 |
1/2 |
1/4 |
| 4TTX3024A1000A |
200/230/1/60 |
24,000 |
.053 |
40 |
33 |
30 |
233 |
76/76 |
12 |
20 |
5/8 |
5/16 |
| 4TTX3030A1000A |
200/230/1/60 |
30,000 |
.059 |
40 |
33 |
30 |
232 |
72/74 |
20 |
30 |
3/4 |
5/16 |
| 4TTX3036A1000A |
200/230/1/60 |
36,000 |
.065 |
40 |
33 |
30 |
245 |
72/74 |
20 |
35 |
3/4 |
3/8 |
| 4TTX3042A1000A |
200/230/1/60 |
42,000 |
.071 |
44 |
33 |
30 |
257 |
76/76 |
25 |
40 |
3/4 |
3/8 |
| 4TTX3048A1000A |
200/230/1/60 |
48,000 |
.077 |
48 |
33 |
30 |
275 |
74/76 |
31 |
50 |
7/8 |
3/8 |
| 4TTX3060A1000A |
200/230/1/60 |
60,000 |
.083 |
42 |
37 |
34 |
307 |
76/78 |
36 |
60 |
7/8 |
3/8 |
XL14i SPLIT SYSTEM AIR CONDITIONING - SINGLE PHASE - 410-A
(10) year warranty on
all functional parts. 14 S.E.E.R.
410A
Air Conditioning Shipping Costs
| Model Number |
Power Supply |
Nom. Cap.
Cooling
(BTUH |
Required
FCCV
Size |
Uncrated
Height
|
Uncrated
Width |
Uncrated
Depth |
Shipping
Weight
(lbs.) |
Sound
Rating |
MCA* |
Max Fuse*
|
Line Size
Gas |
Line Size
Liquid |
| 4TTX4018A1000A |
200/230/1/60 |
18,000 |
.047 |
40 |
33 |
30 |
236 |
76/76 |
10 |
15 |
1/2 |
1/4 |
| 4TTX4024A1000A |
200/230/1/60 |
24,000 |
.053 |
40 |
33 |
30 |
239 |
78/78 |
13 |
20 |
5/8 |
5/16 |
| 4TTX4030A1000A |
200/230/1/60 |
30,000 |
.059 |
40 |
33 |
30 |
242 |
76/74 |
20 |
30 |
3/4 |
5/16 |
| 4TTX4036A1000A |
200/230/1/60 |
36,000 |
.065 |
44 |
33 |
30 |
255 |
74/72 |
21 |
35 |
3/4 |
3/8 |
| 4TTX4042A1000A |
200/230/1/60 |
42,000 |
.071 |
46 |
37 |
34 |
297 |
78/76 |
25 |
40 |
3/4 |
3/8 |
| 4TTX4048A1000A |
200/230/1/60 |
48,000 |
.075 |
50 |
37 |
34 |
310 |
78/75 |
27 |
45 |
7/8 |
3/8 |
| 4TTX4060A1000A |
200/230/1/60 |
60,000 |
.086 |
50 |
37 |
34 |
360 |
78/78 |
39 |
60 |
7/8 |
3/8 |
XL1800 SPLIT SYSTEM AIR CONDITIONING - SINGLE PHASE - R-22
410A REFRIGERANT NOT AVAILABLE UNTIL THE END OF 2002.
Air Conditioning Shipping Costs
| Model Number |
Power Supply |
Nom. Cap.
Cooling
(BTUH |
Required
FCCV
Size |
Uncrated
Height
|
Uncrated
Width |
Uncrated
Depth |
Shipping
Weight
(lbs.) |
Sound
Rating |
MCA* |
Max Fuse*
|
Line Size
Gas |
Line Size
Liquid |
| TTZ036A100A |
200/230/1/60 |
36,000 |
TXV |
43 |
40 |
36 |
450 |
74 |
22 |
35 |
7/8 |
3/8 |
| TTZ048A100A |
200/230/1/60 |
48,000 |
TXV |
43 |
40 |
36 |
460 |
74 |
25 |
40 |
1 1/8 |
3/8 |
| TTZ060A100A |
200/230/1/60 |
60,000 |
TXV |
43 |
40 |
36 |
470 |
74 |
38 |
60 |
1 1/8 |
3/8 |
BRAZED, CASED DUAL CIRCUIT EVAPORATOR COILS
FOR
VARIABLE SPEED GAS FURNACES.
FOR USE WITH (2)
INDIVIDUAL
CONDENSERS.
(below)
| Model Number |
Nominal Cooling Capacity (Btuh) |
Coil Type |
Refrigerant Control |
Outlet Dimensions (in.) W/HXD |
Overall Dimensions (in.) |
Shipping Weight |
| TXC039E300C |
36,000 |
A |
TXVNB * |
15 5/8 X 19 5/16 |
30 X 17 1/2 X 21 1/2 |
69 |
| TXC059E300C |
59,000 |
A |
TXVNB * |
19 1/8 X 19 5/16 |
30 X 21 X 21 1/2 |
73 |
| TXC062E300C |
64,000 |
A |
TXVNB * |
22 5/8 X 19 5/16 |
30 X 24 1/2 X 21 1/2 |
79 |
* Start kits required. Note: These coils are only used with Variable Speed
Gas Furnaces to achieve 2-stage heat/cool.
Air Conditioning Shipping Costs