Google
 
Web www.sheridanhvac.com

  Click here for a free, no obligation price quote from a local HVAC contractor

IF YOU NEED PARTS, PLEASE CLICK THE BANNER BELOW

 

 Clearance Sale on Compressors, Power Washers & Generators

 

Home
Articles:
Lung Cancer and YOUR Furnace or Boiler
CHECK OUT THIS NEW HOMEOWNERS BLOG.
FREE ADS FOR BUSINESSES!
   Homeowners Blog
 CATEGORIES
Table of Contents
Site Map
Contact
Search
Trane Rebates.
New 16 SEER
New 19.5 SEER
Trane Snowball
About Us
Testimonials
FAQ
New Trane Models
Humidifiers
T-Stats
Zoning
Elec.Air Cleaner
Carbon Monoxide
Furnace Repairs
Trane Furnaces
Trane AC Sale
Estimate
Add AC
Boilers
Install Photos
Commercial
Codes/Permits
Tight Homes
Low Air Flow
Heat Exchanger
Tips
Glossary
Troubleshooting
Internet Terms of Use
About Shipping
Equip Specs
Links
 

 

 

 


 



























 

 

 

 

 


Translate this Web Site to French, and other languages.
Tecleo aquí para una traducción española.
Cuando usted hace clic aquí usted irá a un sitio del traductor. Una vez que allí, pulse adentro a www.sheridanhvac.com en el traductor del Web page NO el rectángulo de texto.


AIR CONDITIONING SPECIFICATIONS

Disclaimer:
Installation of any Heating or Cooling equipment must be done by persons trained in this Trade. Serious personal injury or death can occur by improper installations. Further, equipment warranty from the manufacturer will most likely be rejected from faulty installations. Furnaces installed at varying altitudes will require altering equipment parts. L.P. (Propane) installations require changing burner orifices and gas valve regulator springs with the proper factory supplied kit. Fuel pressure will need to be set using special equipment by an H.V.A.C. professional. (2) stage furnaces will require a 2 stage heating thermostat and related wiring for the furnace to function as it should. Pressure switches for your altitude will need to be ordered and the pressure switches in the furnace you receive ( which are installed for the Denver area ) will need to be replaced with these! Refrigerant can not be bought, handled or installed by any one who does not hold a Federal E.P.A. card for the particular refrigerant. Refrigerant may need to be added for the system to operate correctly and to not void the manufacturer's warranty! Sheridan Mechanical Services will not be liable for any installations by others nor will we accept any responsibility for damages to people, equipment, buildings or parts.
Open any shipping cartons and examine contents for damage before accepting delivery so that you may make a claim to the Carrier on the spot as we will not be responsible for damages from shipping.

XB1000 SPLIT SYSTEM AIR CONDITIONING - SINGLE PHASE
(5) year warranty on all functional parts. 10 S.E.E.R. R-22

Air Conditioning Shipping Costs

 

Model Number Power Supply Nom. Cap.
Cooling

(BTUH

Required

FCCV

Size



Uncrated
Height

 

Uncrated
Width
Uncrated
Depth
Shipping
Weight
(lbs.)
Sound
Rating
MCA*

Max Fuse*

 

Line Size
Gas
Line Size
Liquid
TTB012C100A 200/230/1/60 12,000 .049 24 18 18 118 82 11 15 5/8 1/4
TTB018C100A 200/230/1/60 18,000 .049 24 18 18 118 82 11 15 5/8 1/4
TTB024C100A 200/230/1/60 24,000 .057 24 18 18 130 80 15 25 3/4 5/16
TTB030C100A 200/230/1/60 30,000 .065 26 25 25 176 78 18 30 3/4 5/16
TTB036C100A 200/230/1/60 36,000 .071 33 25 25 184 78 22 35 7/8 3/8
TTB042D100A 200/230/1/60 42,000 .077 33 25 25 176 78 28 45 7/8 3/8
TTB048D100A 200/230/1/60 48,000 .083 33 25 25 216 80 30 50 11/8 3/8
TTB060D100A 200/230/1/60 60,000 .092 41 33 29 265 79 38 60 11/8 3/8

XE1000 SPLIT SYSTEM AIR CONDITIONING - SINGLE PHASE
(5) year warranty on all functional parts. 10 S.E.E.R. R-22

Air Conditioning Shipping Costs

 

Model Number Power Supply Nom. Cap.
Cooling

(BTUH

Required

FCCV

Size



Uncrated
Height

 

Uncrated
Width
Uncrated
Depth
Shipping
Weight
(lbs.)
Sound
Rating
MCA*

Max Fuse*

 

Line Size
Gas
Line Size
Liquid
TTR018D100A 200/230/1/60 18,000 .053 24 24 20 144 82 11 15 5/8 1/4
TTR025C100A 200/230/1/60 24,000 .055 24 24 20 144 82 15 25 3/4 5/16
TTR030C100A 200/230/1/60 30,000 .067 28 28 25 162 78 20 30 3/4 5/16
TTR036D100A 200/230/1/60 36,000 .071 28 28 25 163 78 26 45 7/8 3/8
TTR042D100A 200/230/1/60 42,000 .080 28 28 25 208 78 28 45 7/8 3/8
TTR048D100A 200/230/1/60 48,000 .083 33 33 29 213 78 31 50 11/8 3/8
TTR060D100A 200/230/1/60 60,000 .092 33 33 29 259 79 38 60 11/8 3/8

XR12 SPLIT SYSTEM AIR CONDITIONING - SINGLE PHASE - R-22
(10) year warranty on compressor and coil, (5) years all functional parts. 12 S.E.E.R. R-22

Air Conditioning Shipping Costs

 

Model Number Power Supply Nom. Cap.
Cooling

(BTUH

Required

FCCV

Size



Uncrated
Height

 

Uncrated
Width
Uncrated
Depth
Shipping
Weight
(lbs.)
Sound
Rating
MCA*

Max Fuse*

 

Line Size
Gas
Line Size
Liquid
2TTR2018A1000A 200/230/1/60 18,000 .051 26 29 26 171 NA 10 15 5/8 1/4
2TTR2024A1000A 200/230/1/60 24,000 .057 29 29 26 187 NA 11 15 3/4 5/16
2TTR2030A1000A 200/230/1/60 30,000 .065 29 29 26 180 NA 15 25 3/4 5/16
2TTR2036A1000A 200/230/1/60 36,000 .071 33 29 26 195 NA 19 30 7/8 3/8
2TTR2042A1000A 200/230/1/60 42,000 .077 33 30 30 228 NA 24 40 7/8 3/8
2TTR2048A1000A 200/230/1/60 48,000 .086 37 30 30 247 NA 26 45 11/8 3/8
2TTR2060A1000A 200/230/1/60 60,000 .095 37 30 30 270 NA 38 60 11/8 3/8

XR12 SPLIT SYSTEM AIR CONDITIONING - SINGLE PHASE - 410-A
(10) year warranty on compressor and coil, (5) years all functional parts. 12 S.E.E.R. 410A

Air Conditioning Shipping Costs

Model Number Power Supply Nom. Cap.
Cooling

(BTUH

Required

FCCV

Size



Uncrated
Height

 

Uncrated
Width
Uncrated
Depth
Shipping
Weight
(lbs.)
Sound
Rating
MCA*

Max Fuse*

 

Line Size
Gas
Line Size
Liquid
4TTR2018A1000A 200/230/1/60 18,000 .049 33 33 30 215 77 10 15 1/2 1/4
4TTR2024A1000A 200/230/1/60 24,000 .053 33 33 30 219 78 13 20 5/8 5/16
4TTR2030A1000A 200/230/1/60 30,000 .059 33 33 30 218 74 20 30 3/4 5/16
4TTR2036A1000A 200/230/1/60 36,000 .065 33 33 30 231 77 21 35 3/4 3/8
4TTR2042A1000A 200/230/1/60 42,000 .071 37 33 30 243 78 25 40 3/4 3/8
4TTR2048A1000A 200/230/1/60 48,000 .077 41 33 30 260 79 31 50 7/8 3/8
4TTR2060A1000A 200/230/1/60 60,000 .083 33 37 34 283 81 36 60 7/8 3/8

XL13i SPLIT SYSTEM AIR CONDITIONING - SINGLE PHASE - 410-A
(10) year warranty on all functional parts. 13 S.E.E.R. 410A

Air Conditioning Shipping Costs

 

Model Number Power Supply Nom. Cap.
Cooling

(BTUH

Required

FCCV

Size



Uncrated
Height

 

Uncrated
Width
Uncrated
Depth
Shipping
Weight
(lbs.)
Sound
Rating
MCA*

Max Fuse*

 

Line Size
Gas
Line Size
Liquid
4TTX3018A1000A 200/230/1/60 18,000 .049 40 33 30 230 74/76 10 15 1/2 1/4
4TTX3024A1000A 200/230/1/60 24,000 .053 40 33 30 233 76/76 12 20 5/8 5/16
4TTX3030A1000A 200/230/1/60 30,000 .059 40 33 30 232 72/74 20 30 3/4 5/16
4TTX3036A1000A 200/230/1/60 36,000 .065 40 33 30 245 72/74 20 35 3/4 3/8
4TTX3042A1000A 200/230/1/60 42,000 .071 44 33 30 257 76/76 25 40 3/4 3/8
4TTX3048A1000A 200/230/1/60 48,000 .077 48 33 30 275 74/76 31 50 7/8 3/8
4TTX3060A1000A 200/230/1/60 60,000 .083 42 37 34 307 76/78 36 60 7/8 3/8

XL14i SPLIT SYSTEM AIR CONDITIONING - SINGLE PHASE - 410-A
(10) year warranty on all functional parts. 14 S.E.E.R. 410A

Air Conditioning Shipping Costs

 

Model Number Power Supply Nom. Cap.
Cooling

(BTUH

Required

FCCV

Size



Uncrated
Height

 

Uncrated
Width
Uncrated
Depth
Shipping
Weight
(lbs.)
Sound
Rating
MCA*

Max Fuse*

 

Line Size
Gas
Line Size
Liquid
4TTX4018A1000A 200/230/1/60 18,000 .047 40 33 30 236 76/76 10 15 1/2 1/4
4TTX4024A1000A 200/230/1/60 24,000 .053 40 33 30 239 78/78 13 20 5/8 5/16
4TTX4030A1000A 200/230/1/60 30,000 .059 40 33 30 242 76/74 20 30 3/4 5/16
4TTX4036A1000A 200/230/1/60 36,000 .065 44 33 30 255 74/72 21 35 3/4 3/8
4TTX4042A1000A 200/230/1/60 42,000 .071 46 37 34 297 78/76 25 40 3/4 3/8
4TTX4048A1000A 200/230/1/60 48,000 .075 50 37 34 310 78/75 27 45 7/8 3/8
4TTX4060A1000A 200/230/1/60 60,000 .086 50 37 34 360 78/78 39 60 7/8 3/8

XL1800 SPLIT SYSTEM AIR CONDITIONING - SINGLE PHASE - R-22
410A REFRIGERANT NOT AVAILABLE UNTIL THE END OF 2002.
Air Conditioning Shipping Costs
Model Number Power Supply Nom. Cap.
Cooling

(BTUH

Required

FCCV

Size



Uncrated
Height

 

Uncrated
Width
Uncrated
Depth
Shipping
Weight
(lbs.)
Sound
Rating
MCA*

Max Fuse*

 

Line Size
Gas
Line Size
Liquid
TTZ036A100A 200/230/1/60 36,000 TXV 43 40 36 450 74 22 35 7/8 3/8
TTZ048A100A 200/230/1/60 48,000 TXV 43 40 36 460 74 25 40 1 1/8 3/8
TTZ060A100A 200/230/1/60 60,000 TXV 43 40 36 470 74 38 60 1 1/8 3/8

BRAZED, CASED DUAL CIRCUIT EVAPORATOR COILS  FOR VARIABLE SPEED GAS FURNACES.
FOR USE WITH (2) INDIVIDUAL CONDENSERS. (below)

Model Number Nominal Cooling Capacity (Btuh) Coil Type Refrigerant Control Outlet Dimensions (in.) W/HXD Overall Dimensions (in.) Shipping Weight
TXC039E300C 36,000 A TXVNB * 15 5/8 X 19 5/16 30 X 17 1/2 X 21 1/2 69
TXC059E300C 59,000 A TXVNB * 19 1/8 X 19 5/16 30 X 21 X 21 1/2 73
TXC062E300C 64,000 A TXVNB * 22 5/8 X 19 5/16 30 X 24 1/2 X 21 1/2 79

* Start kits required. Note: These coils are only used with Variable Speed Gas Furnaces to achieve 2-stage heat/cool.
Air Conditioning Shipping Costs

Back to Equip. Specs.

 

 

 


 

All photos and text are original material published by Sheridan Mechanical Services 
and can not be distributed, or republished without written permission from 
Sheridan Mechanical Services.

UPDATED 09/12/2007 06:36 AM

© Copyright2001, 2002, 2003, 2004, 2005, 2006.  Sheridan Mechanical Services. All rights reserved.